McDATA OPENconnectors Command Line Interace Bedienungsanleitung Seite 315

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 406
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 314
A
Error Messages
A-13
Message Error 083: Not Allowed in Open Fabric Mode
Description This request cannot be completed while this switch is operating in
Open Fabric 1.0 mode.
Action Configure the interop mode to McDATA Fabric 1.0 mode.
Message Error 088: Invalid Feature Key Length
Description The feature key installed is longer than the maximum length allowed.
Action Be sure that the key has been entered correctly and re-submit.
Contact your sales representative with any further problems.
Message Error 090: Invalid Port Type
Description The port type configured is invalid.
Action A port may be configured to be an eport, gport, or fport. Be sure the
port is configured appropriately and re-submit the command.
Message Error 091: E_Port Type Configured
Description Ports are not allowed to be configured as E_Ports in S/390 mode.
Action Configure the port as either a fport or gport and resubmit the
command.
Message Error 092: Not Allowed While Port Is Unblocked
Description The port must be blocked to complete this request.
Action Block the port and re-submit the command.
Message Error 093: Not Allowed While FICON MS Is Installed
Description This request cannot be completed because FICON Management
Server is installed.
Action This operation is not supported. No action necessary.
Seitenansicht 314
1 2 ... 310 311 312 313 314 315 316 317 318 319 320 ... 405 406

Kommentare zu diesen Handbüchern

Keine Kommentare