A-28
McDATA Sphereon 4400 Fabric Switch Installation and Service Manual
Event Code Tables
Fan Events (300 through 399)
Event Code: 300
Message: Cooling fan propeller failed.
Severity: Major.
Explanation: One cooling fan failed or is rotating at insufficient angular velocity.
Action: Replace the switch.
Event Data: The first byte of event data (byte 0) specifies the failed fan number.
Distribution: Product Management Server Host
EFCM Basic
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Log
✔✔✔✔✔✔
Event Code: 301
Message: Cooling fan propeller failed.
Severity: Major.
Explanation: Two cooling fans failed or are rotating at insufficient angular velocity.
Action: Replace the switch.
Event Data: The first byte of event data (byte 0) specifies the failed fan number(s).
Distribution: Product Management Server Host
EFCM Basic
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Log
✔✔✔✔✔✔