McDATA 1U Server Wartungshandbuch Seite 103

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 316
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 102
2
Task 19: Configure the Element Manager Application
2-61
Installation Tasks
3. Click Activate to save the information and close the dialog box.
Configure Product
Parameters
Follow the procedures in this section to configure product operating
parameters.
1. Set the product offline. Refer to Setting Online State for
instructions.
2. Select Operating Parameters from the Configure menu
(Configure>Operating Parameters).
3. Click the Domain tab (Figure 2-29).
Figure 2-29 Configure Switch Parameters Dialog Box
a. Select the Domain ID Offset value from the drop-down list.
Values available in the drop-down list are 0, 32, 64, 96
(default), 128, 160, and 192. Domain IDs minus the offset are
still in the 1-31 range.
b. Type a value between 1 - 31 in the Preferred Domain ID field.
This value uniquely identifies each fabric element. At the
Preferred Domain ID field, type a value between 1 through 31.
This value uniquely identifies each fabric element.
Seitenansicht 102
1 2 ... 98 99 100 101 102 103 104 105 106 107 108 ... 315 316

Kommentare zu diesen Handbüchern

Keine Kommentare