McDATA 1U Server Wartungshandbuch Seite 158

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 316
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 157
3
3-34
McDATA Sphereon 4400 Fabric Switch Installation and Service Manual
Maintenence Analysis Procedures
Was the maintenance action successful?
NO YES
The product port is operational. Exit MAP.
Contact the next level of support. Exit MAP.
13
As indicated by event code 083, a port is set to an inactive state.
a. At the Event Log, examine the first two bytes of event data.
b. Byte 0 specifies the port reporting the problem. Byte 1 specifies
the inactive reason as listed in Ta bl e 3- 1 2.
14
A port is inactive because Flexport Technology is disabled. Install the
Flexport Technology PFE key to enable N_Port capability. Refer to
Installing PFE Keys (Optional) (EFCM Basic Edition) or Tas k 1 6 :
Configure PFE Key (Optional) (Element Manager). Exit MAP.
15
A port is inactive because the:
Port cannot operate at the product (backplane) speed.
Optical transceiver does not support the configured port speed.
Change the port speed to be compatible with the backplane or optical
transceiver speed.
a. For the product reporting the problem:
EFCM Basic Edition - Select Ports and Basic Info from the
Configure menu at any view. The Basic Information View
displays.
Table 3-12 Inactive Port Reasons and Actions
Byte 1 Inactive Port Reason Action
02 Feature key not enabled. Go to step 14.
03 Switch speed conflict. Go to step 15.
04 Optics speed conflict. Go to step 15.
06 Port swap conflict. Go to step 16.
Seitenansicht 157
1 2 ... 153 154 155 156 157 158 159 160 161 162 163 ... 315 316

Kommentare zu diesen Handbüchern