2
CLI Commands
2-145
show
Output The event log data are displayed as a table that includes the following
properties.
Output Example The output from the show.eventLog command displays as follows.
Date/Time Code Severity FRU Event Data
---------------- ---- -------- ----- -----------------------------------
04/12/01 10:58A 375 Major CTP-0 00010203 04050607 08090A0B 0C0D0E0F
04/12/01 9:58A 385 Severe CTP-0 00010203 04050607 08090A0B 0C0D0E0F
04/11/01 7:18P 395 Severe CTP-0 00010203 04050607 08090A0B 0C0D0E0F
show.fabricLog.noWrap
Syntax noWrap [clear]
Purpose This command allows the user to view the contents of the
non-wrapping region of the fabric log. The log entries will not persist
IMLs or power cycles; it will not be stored in NV RAM.
NOTE: This log will not wrap. The log will stop collecting entries after is it
filled.
Date/Time The date and time when the event occurred.
Code The event reason code.
Severity The severity of the event. The values are:
• Major—Unit operational (major failure).
• Minor—Unit operational (minor failure).
• Severe—Unit not operational. The causes are
either that the switch contains no operational
SBAR cards or that the system shuts down
due to CTP thermal threshold violations.
• Info—Unit operational (information only).
FRU The FRU and FRU position, where applicable.
Event Data The 32-byte hexadecimal description of the
event in words.